How to sample olive oil from tanks, IBCs and tins

At least three levels in a tank, a set number of packages per batch, three sample sets and a reference sample. Whether a result describes the batch depends on these steps.

To get a representative olive oil sample from a tank, take samples at equal intervals from the top downwards at no fewer than three levels and combine them; for packaged oil, select at random a number of packages set by the batch size. Türkiye's commercial quality inspection communiqué spells out these steps for olive oil, while the IOC standard and the EU regulation rely on ISO 5555. The sample is then sealed, a reference sample is set aside, and everything is kept dark and cool.

Why isn't a bottle from the tap enough?

An analysis report describes the bottle that reached the laboratory. Whether that bottle represents the batch is decided by the person who took it. Oil standing in a tank settles, with sediment at the bottom and the surface exposed to air, and oil added later does not always spread evenly. A single bottle from a tap near the bottom may not describe the whole tank.

Start by defining the batch. Under Türkiye's Commercial Quality Inspection Communiqué (No. 2026/21), olive oil of the same grade, type and batch number presented for inspection at one time counts as one batch. Combining oils of different grades or batch numbers into one composite gives a result that describes none of them.

What should happen before sampling?

The Communiqué's general rules are a good starting point for your own procedure:

  • Take samples indoors where possible, and avoid anything that could contaminate the oil.
  • Wash the sampling tool and containers with hot soapy water or detergent, rinse with hot water until no trace remains, then dry them.
  • For oils where aroma and taste matter, steam cleaning of tools and containers is also advised. This matters if the virgin oil is going to a sensory panel.

How is each container sampled?

ContainerBasisHow to sampleResult
Storage vessel, tank, ship's tank, rail tankerNo. 2026/21, TS 341 entryWith a suitable tool, from the top downwards, equal intervals, at least three levelsThree sets of 1 litre from the composite
Drums and similar containers above 18 litres, sealed packs below 18 litresNo. 2026/21, TS 341 entrySelect packages by schedule, mix each containerThree 1000 ml combined samples plus acidity samples
Packages up to 5 litresEU 2022/2105, Annex IIOne package if at least 750 ml; otherwise enough packages to total 750 mlPrimary sample
Packages above 5 litresEU 2022/2105, Annex IITake from randomly selected packages, then mixUnits of at least 1 litre

The Turkish schedule sets aside 2 packages for up to 25, 3 for 26-150, 5 for 151-1,200, 8 for 1,201-35,000 and 13 for 35,001 and above. Packages are chosen at random from units separated systematically across the batch. An equal amount comes from each container: three acidity samples of at least about 50 ml each, and about 500 ml for the combined sample. Small packages up to one litre are taken sealed.

Under the EU rule for packages above 5 litres, the number of packages is 1 for up to 10, 2 for 11-150, 3 for 151-500, 4 for 501-1,500 and 5 for 1,501-2,500, plus one for each further 1,000. The number of primary samples also rises with batch volume: 2 below 7,500 litres, 3 below 25,000 litres and 4 below 75,000 litres. The rule is strict: if one primary sample fails, the whole batch is non-compliant.

What about IBCs?

The Communiqué does not name IBCs. Our suggestion is to treat a single IBC like a small tank and sample at least three levels from the top down. If several IBCs belong to the same batch, take equal amounts from each and make a composite; if they were filled separately, treat them as separate batches. If the sample is going to an official inspection, ask the inspection unit how it handles them first. The 2014 amendment to ISO 5555 also adds a section on flexi-tanks.

How should samples be stored and recorded?

  • Prepare three sets. Under the Communiqué, two sets go unopened to the laboratory as analysis and reference samples, and one stays with the inspection unit. In a commercial purchase, buyer and seller can each hold a set on the same logic.
  • Seal them together. The Communiqué has the inspector and the company seal the samples together and attach a signed sample card.
  • Keep them dark and cool. EU Regulation 2022/2105 requires samples to be kept in a dark place away from heat and sent to the laboratory by the fifth working day. In practice, a dark container with little headspace also helps.
  • Label fully. Batch number, tank or package number, date and the person sampling. The number on the report and on the purchase record must match.

The Communiqué keeps samples for up to sixty days, or until any dispute between buyer and seller is resolved. Setting your own retention period in writing also helps if a dispute arises.

Does your own sample replace an official one?

No. Under the Turkish Food Codex Communiqué on Olive Oil, official samples follow the regulation on official controls of food and feed. A company's own sample supports purchasing and quality decisions. We explain this difference in where olive oil is analysed.

Is an Olivex reading independent of sampling?

No. A field reading also uses a small sample of a few drops and describes the oil those drops came from. Take the Olivex reading from the composite and link the result to the batch record, then send the sealed sample to the laboratory for any suspect batch. The field steps are in how we work.

Sources

Meeting request

Let's try the analysis set in your operation and discuss where and how often you would be reading.

The first meeting reviews your product, sales channels and the risks you face, and recommends a suitable method.

Request a meeting